Grade:
Industry: 99.5%
Electronic UPS: 99.9%, metal impurities < 1ppm
Pharmaceutical: USP grade
Wrap:
20KG/Drum, 160KG/Steel Drum.
Applications of acetone:
Industrial Solvents – Acetone is widely used as a solvent in industries such as pharmaceuticals, plastics, and textiles due to its ability to dissolve many organic compounds.
Chemical synthesis – It is a precursor for the production of chemicals such as methyl methacrylate (MMA), bisphenol A (BPA), and various resins.
Cosmetics & Personal Care – Acetone is a key ingredient in nail polish removers that are also used in skin care and chemical peels.
Detergent – It is used as a degreaser for cleaning machinery, electronics, and lab equipment.
Paints and coatings – Acetone is an effective thinner and remover used in paints, varnishes, and adhesives.
Pharmaceuticals – It is used as an excipient in the production of drugs and pharmaceutical formulations.
Automotive & Aerospace – Acetone is used in fuel additives, cleaners for engine components, and composites.
Laboratory Reagent – It is commonly used as a solvent and cleaning agent in scientific research and laboratories.
Textile industry – Acetone is used in the manufacture of synthetic fibers such as rayon and in dyeing processes.
Explosives and pyrotechnics – It plays a role in the synthesis of certain explosive compounds.
Hazard identification2.1
Classification of substances or mixtures
Flammable liquids, (Class 2) H225: Highly flammable liquids and vapors.
Eye irritation, (Category 2) H319: Causes severe eye irritation.
Specific Target Organ Toxicity –
Single Exposure, (Class 3),
Respiratory
H336: May cause drowsiness or dizziness.

Certificate of Industrial Analysis
Product name |
acetone |
molecular formula |
CH₃COCH₃ |
molecular weight |
58.08 |
specification |
Industrial grade |
lot number |
2022103101 |
Batch quantity |
30 tons |
Submit the unit |
Production Department |
Sample category |
organic |
Report date |
2022.11.02 |
Test the basics |
GB/T 6026-2013 |
Test results
Test items |
Standard requirements: |
Actual results |
Purity (%) |
≥99.5 |
99.7 |
appearance |
Clear liquids |
Clear liquids |
|
≤5 |
≤5 |
Density (20°C) (g/cm³). |
0.789 ~ 0.791 |
0.790 |
Boiling Range (0°C, 101.3 kPa) (including 56.1°C) (°C).
|
≤0.7 |
0.6 |
Evaporation Residue (%) |
≤0.002 |
0.0008 |
Acidity (in terms of acetic acid) (%) |
≤0.002 |
0.0003 |
Potassium Permanganate Test (25°C) (min) |
≥120 |
121 |
water solubility |
qualified |
qualified |
Moisture content (%) |
≤0.30 |
0.20 |
Methanol (%) |
≤0.05 |
0.02 |
Arsenic (mg/kg) |
≤5 |
2 |
UPS Certificate of Analysis
Product name |
acetone |
molecular formula |
CH₃COCH₃ |
molecular weight |
58.08 |
specification |
Electronic UPS ratings |
lot number |
2025020701 |
Batch quantity |
500 kg |
Submit the unit |
Production of the first part |
Sample category |
organic |
Report date |
2025.02.10 |
Inspection standards |
Enterprise standards |
Test results
Test items |
Standard requirements: |
Measurement results |
Purity (%) |
≥99.8 |
99.8 |
appearance |
Colorless transparent liquid |
Colorless transparent liquid |
Color/Blackness Unit |
≤10 |
≤10 |
Particles (≥0.5 μm) / mL |
≤10 |
≤10 |
Particles (≥0.2 μm) / mL |
≤200 |
≤200 |
Water Content (H₂O, %) |
≤0.2 |
0.08 |
Acidity (as H⁺, mmol/g) |
≤0.0005 |
0.0001 |
Water Solubility Test |
Pass |
Pass |
Reducing Permanganate Substance |
Pass |
Pass |
Trace Metal Elements (ppb)
Element |
Standard Requirement |
Measured Result |
Sodium (Na) |
≤1 |
≤1 |
Magnesium (Mg) |
≤1 |
≤1 |
Aluminum (Al) |
≤1 |
≤1 |
Potassium (K) |
≤1 |
≤1 |
Calcium (Ca) |
≤1 |
≤1 |
Chromium (Cr) |
≤1 |
≤1 |
Iron (Fe) |
≤1 |
≤1 |
Nickel (Ni) |
≤1 |
≤1 |
Lithium (Li) |
≤1 |
≤1 |
Zinc (Zn) |
≤1 |
≤1 |
Titanium (Ti) |
≤1 |
≤1 |
Manganese (Mn) |
≤1 |
≤1 |
Cobalt (Co) |
≤1 |
≤1 |
Copper (Cu) |
≤1 |
≤1 |
Gallium (Ga) |
≤1 |
≤1 |
Arsenic (As) |
≤1 |
≤1 |
Thallium (Tl) |
≤1 |
≤1 |
Cadmium (Cd) |
≤1 |
≤1 |
Antimony (Sb) |
≤1 |
≤1 |
Barium (Ba) |
≤1 |
≤1 |
Gold (Au) |
≤1 |
≤1 |
Lead (Pb) |
≤1 |
≤1 |
USP Certificate of Analysis
Inspection Report No.: CoA-FP008—2023/001
Product Name |
Acetone (USP) |
Identification Code |
F08 |
Grade |
Pharmaceutical Excipient |
Packaging Specification |
20kg/barrel |
Batch Number |
F-231001 |
Batch Quantity |
97 barrels |
Inspection Department |
Please Inspect |
Sampling |
4L |
Sampling Date |
2023.11.01 |
Inspection Date |
2023.11.01 |
Report Date |
2023.11.30 |
Inspection Standard |
USP42 |
Test Results
Test Item |
Quality Standard |
Test Result |
Appearance |
Clear, colorless liquid |
Clear, colorless liquid |
Identification |
(1) Infrared absorption spectrum should match the reference spectrum |
Infrared absorption spectrum matches the reference spectrum |
|
(2) The retention time of the main peak in the sample solution should match the retention time of the acetone reference standard |
Complies |
Specific Gravity (25°C) |
Not higher than 0.789 |
0.786 |
Non-volatile Residue |
Residue weight should not exceed 2mg (0.004%) |
1.35mg |
Volatile Impurities |
The high concentration chromaticity of the solution should not completely disappear within 15 minutes |
Complies |
Water Content |
After removing air bubbles, the peak area of water in the sample solution should not be greater than 0.5% of the peak area of acetone solution |
Complies |
Purity |
Acetone content should not be less than 99.0% |
99.82% |
Microbial Limits |
Total aerobic microbial count should not exceed 10³ cfu/ml |
<1 cfu/ml |
|
Total yeast and mold count should not exceed 10² cfu/ml |
<1 cfu/ml |